Battery
Typical backup time at half load:The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
9 min
Battery technology:The type of battery in the device, e.g. nickel–cadmium (NiCd).
Sealed Lead Acid (VRLA)
Design
Safety:List of regulatory safety standards for all countries in which this product has been certified.
IEC 62040-1, IEC 60950-1, IEC 62040-2, CB Report, CE mark, IEC 61643-1
LED indicators:
Battery replacement
Rack capacity:The spase that device fill in rack.
2U
Form factor:The shape or design of the product.
Tower
Features
Audible alarm modes:
Battery replacement
Audible alarm(s):Alarms that make a sound when they are activated (set off).
Surge protection features:
Fax, Modem, Network, Telephone
Emergency Power Off (EPO):
Output operation voltage (max):The maximum output voltage produced by the device.
240 V
Output operation voltage (min):The minumum voltage produced by the device during operation.
220 V
Input frequency:The frequency (Hz) which is required to power the product.
50/60 Hz
Input operation voltage (max):The maximum input voltage supported by the device.
284 V
Input operation voltage (min):The minumum voltage needed by the device during operation.
161 V
Output power:The power that the device can produce.
400 W
Output power capacity:The maximum power that the device can produce.
0.65 kVA
UPS topology:
Standby (Offline)
Logistics data
Harmonized System (HS) code:
85078000
Other features
Nominal input voltage:The voltage which the manufacturer recommends that the device needs to operate normally.
230 V
Nominal output voltage:The voltage which the manufacturer states that the device can produce.
220-240 V
Input connection type:The type of connection /port for the input(s) into this device e.g. USB.
IEC
Ports & interfaces
Ethernet LAN (RJ-45) ports:Number of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
1
AC outlets quantity:The number of sockets in the device where AC electrical power can be connected.
4 AC outlet(s)
Power plug:A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
C14 coupler
AC outlet types:The type of outlet for AC electricity.
C13 coupler
Weight & dimensions
Weight:Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
3.6 kg
Height:The measurement of the product from head to foot or from base to top.
263 mm
Depth:The distance from the front to the back of something.
235 mm
Width:The measurement or extent of something from side to side.
81 mm